Skip to content
Driven by technology and the environment. Heating systems for the future.
Contact us
Menu

YINENG PRODUCTS

WNS Oil/Gas-Fired Energy-Saving Steam Boiler

Model / Series WNS

A three-pass wet-back shell boiler with an economizer for flue-gas heat recovery. Evaporation is 1–20 t/h and design efficiency 92.2–93.2%.

Atomized fuel burns in the fully corrugated furnace, transferring radiant heat in the first pass. Gas collects in the reversal chamber and enters the second-pass threaded smoke tubes, then turns at the front smokebox into the third-pass plain-tube bank before exiting through the rear smokebox, economizer and chimney.

Design and features

Hinged smokebox

A hinged smokebox supports inspection and cleaning while improving sealing.

Corrugated furnace

Corrugations increase heating surface and disturb gas flow for heat transfer, improve furnace flexibility and strength, and reduce thermal-expansion stress.

Threaded smoke tubes

Threaded tubes increase heating area and flue-gas residence time within limited space. Heat-transfer performance is 1.3 times that of ordinary smoke tubes.

Furnace and steam space

Provides steam storage space and heating surface.

Flue-gas heat recovery

The economizer and illustrated condenser recover gas heat to raise feedwater temperature and lower exhaust temperature. Finned tubes increase surface area; the condenser uses ND steel.

Calculation basis: lower heating values of 8400 kcal/Nm³ for natural gas and 10250 kcal/kg for diesel. Y denotes oil firing and Q denotes gas firing.

PRODUCT DATA

Specifications

WNS Fully Automatic Oil/Gas-Fired Energy-Saving Steam Boiler
Model WNS1 WNS1.5 WNS2 WNS3 WNS4 WNS6 WNS8 WNS10 WNS12 WNS15 WNS20
Rated evaporation t/h 1 1.5 2 3 4 6 8 10 12 15 20
Rated steam pressure MPa 1.25(1.6)
Rated steam temperature ℃ 194(204)
Rated feedwater temperature ℃ 20 20(104)
Boiler body heating surface m2 25.5 39.1 51.3 82.3 105 160.7 205.9 246.1 287.2 374.8 492.3
Economizer heating surface m2 6 8.9 10.8 17.1 20.2 26.4 41.7 40.3 46.4 49.8 66.1
Design thermal efficiency % 92.2 92.5 93.2 92.8 92.4 92.5 92.7 92.2 92.8 92.8 92.7
Design ambient temperature ℃ 20
Boiler net weight t 6.3 8.1 9.5 12.2 13.5 18.9 23.5 25.6 26.8 35 42.5
Boiler operating water capacity t 2.8 3.7 4.7 6.6 8.1 11.5 15.3 18.9 20.7 28.1 37.8
Boiler full-water capacity t 3.4 4.5 5.9 7.9 9.6 12.7 18 22.3 24 31.6 33.9
Boiler feedwater control On/off feedwater control Modulating feedwater control
Combustion mode Slight-positive-pressure chamber combustion
Natural gas Nm3/h 80.1 118.7 160.1 236 314.8 479.8
(407.8)
631.7
(553.3)
790.3
(691.1)
944.5
(825.3)
1173.2
(1016.6)
1545.3
(1342)
Diesel kg/h 68.2 101.9 136.2 200.7 271.8 408.8
(347.3)
546.7
(476.4)
679.3
(599)
803.7
(711.9)
1000
(895.3)
1323.9
(1161)
Transport dimensions Length mm 3900 4080 4300 4690 5250 6100 6200 6853 6950 7520 8030
Width 1900 2090 2100 2350 2550 2710 2920 3210 3310 3620 3780
Height 2110 2240 2400 2502 2750 2980 3280 3500 3630 3820 4100
Installation dimensions Length mm 4630 4750 5100 5680 6350 7450 7700 8230 8355 9580 10560
Width 2800 2990 3000 3250 3450 3610 3820 4110 4210 4520 5000
Height 3630 3760 3900 4030 4600 4900 5200 5650 5850 5900 6000
Feedwater connection DN mm 32 32 40 40 40 40 50 50 50 65 65
Main steam outlet DN mm 50 65 80 80 100 125 150 150 150 200 200

Related products

CONTACT YINENG

Discuss your heating requirements

Contact Hebei Yineng Boiler Co., Ltd. for product information.

Contact us