Skip to content
Driven by technology and the environment. Heating systems for the future.
Contact us
Menu

YINENG PRODUCTS

SZS Oil/Gas-Fired Hot Water Boiler

Model / Series SZS

A longitudinal twin-drum D-type hot-water boiler, with heat outputs of 7–28 MW and design efficiency of 96.5–96.7%.

The two drums are arranged longitudinally in a D layout, with the furnace on the right and convective banks on the left. Movable supports at the lower drum center and ends allow expansion toward both ends. Rear convective tubes are more widely spaced and staggered, with in-line tubes at the front. Gas leaves the furnace rear, enters the burnout chamber and convective banks, then turns at the left front into the heat-recovery surfaces before chimney discharge.

A spiral-finned-tube condensing economizer is used at the tail end. The hinged smokebox and front/rear inspection doors aid maintenance and cleaning.

Design and features

D-type membrane-wall construction

Membrane water walls surround the furnace; the left wall seals it from the convective banks. Walls and upper/lower drums are fully seal-welded to limit gas bypass and water leakage.

Insulation and gas tightness

High-density aluminum-silicate insulation and castable material reduce body weight, with radiant-heat insulation measures. The gas side operates sealed at slight positive pressure to reduce air leakage; no separate forced-draft fan is required.

Explosion-relief door and access

A spring-loaded top explosion-relief door provides pressure relief, while inspection doors and manholes provide maintenance access.

Calculation basis: lower heating values of 8400 kcal/Nm³ for natural gas and 10250 kcal/kg for diesel. Y denotes oil firing and Q denotes gas firing.

PRODUCT DATA

Specifications

SZS Fully Automatic Oil/Gas-Fired Hot Water Boiler
Boiler model SZS7.0 SZS10.5 SZS14 SZS17.5 SZS21 SZS24.5 SZS29
Rated heat output MW 7 10.5 14 17.5 21 24.5 28
Rated water outlet pressure MPa 1 1.25 1.25 1.25 1.6 1.6 1.6
Rated water outlet temperature ℃ 115/130
Rated return-water temperature ℃ 70
Design thermal efficiency % 96.5 96.5 96.6 96.6 96.6 96.7 96.7
Design ambient temperature ℃ 20
Boiler net weight t 28 36 40 42 48 51 58
Boiler water capacity t 9.2 11.2 14.6 15.8 18.9 24.7 30.1
Combustion mode Slight-positive-pressure chamber combustion
Natural gas 740 1112 1492 1864 2231 2613 3085
Diesel 615 915 1223 1538 1847 2155 2549
Transport dimensions Length mm 7600 9100 9500 9500 9850 10000 11000
Width 2750 3450 3530 3710 3890 4150 4270
Height 3680 3800 3950 4050 4200 4250 4300
Water outlet DN mm 200 200 200 200 250 250 250
Return-water connection DN mm 200 200 200 200 250 250 250
Manual blowdown connection DN mm 50 50 50 50 50 50 50
Safety valve DN mm 2×80 2×100 2×100 2×125 2×150 2×150 2×200

Related products

CONTACT YINENG

Discuss your heating requirements

Contact Hebei Yineng Boiler Co., Ltd. for product information.

Contact us