Molten Salt Heater

Model / Series RY(Q)

Uses a molten salt mixture such as potassium nitrate and sodium nitrite. The system includes a heater, salt pump and melting system; powers span 500–8200 kW.

Powdered salt is heated above its melting point until its viscosity permits pumping, then circulated through the heater for further heating and use. The table lists working pressure 0.8 MPa, design pressure 1 MPa and outlet temperatures of 430 or 450 degrees by model.

Design and features

Multilayer coils

Double- or multilayer coils are secured by welded round steel. Radiant and convective sections are configured for heat transfer, with radiant-section flue-gas temperature monitoring.

Top protection and insulation

Top coils protect the furnace wall. Double-layer aluminum-silicate insulation is described as limiting surface temperature to 25 degrees above room temperature.

Split delivery

Upper and lower sections are transported separately and assembled on site.

PLC control and remote connectivity

Automatic combustion regulation is interlocked with expansion-tank level, inlet/outlet temperatures and flow monitoring. Unattended operation, a remote app and DCS integration can be configured.

Calculation basis: lower heating values of 8400 kcal/Nm³ for natural gas and 10250 kcal/kg for diesel. Y denotes oil firing and Q denotes gas firing.

PRODUCT DATA

Specifications

Product model RY(Q)
450kw
RY(Q)
450kw
RY(Q)
1000kw
RY(Q)
1200kw
RY(Q)
1400kw
RY(Q)
2000kw
RY(Q)
2400kw
Rated power KW 500 700 930 1200 1400 2000 2400
Equivalent heat output 10,000 kcal/h 40 60 80 100 120 160 200
Working pressure MPa 0.8
Design pressure MPa 1
Salt inlet temperature Degrees 430 430 430 432 428 420 420
Salt outlet temperature Degrees 450
Boiler flow m³/h 28 50 80 80 80 100 120
Boiler net weight t 4.7 6.4 6.7 6.9 7.5 9.7 10.8
Fuel consumption Natural gas Nm³/h 57 89 102 152 178 254 305
Light oil kg/h 47 73 84 126 147 209 252
Continued
Item Model RY(Q)
3000kw
RY(Q)
3500kw
RY(Q)
4100kw
RY(Q)
4700kw
RY(Q)
6000kw
RY(Q)
7000kw
RY(Q)
8200kw
Rated power KW 3000 3500 4100 4700 6000 7000 8200
Equivalent heat output 10,000 kcal/h 250 300 350 400 500 600 700
Working pressure MPa 0.8
Design pressure MPa 1
Salt inlet temperature Degrees 420 423 400 422 412 420 414
Salt outlet temperature Degrees 450 430 450
Boiler flow m³/h 160 160 160 200 200 280 280
Design thermal efficiency Oil
(gas)
% 96
(98.02)
96.1
(98.03)
96.01
(98.06)
96.2
(98.07)
96.18
(98.04)
96.17
(98.08)
92.98
(92.15
)
Boiler net weight t 16.3 17.5 19.1 27 30 38 43
Fuel consumption Natural gas Nm³/h 380 445 520 599 763 889 1041
Light oil kg/h 314 367 430 495 630 734 860