YINENG PRODUCTS
Horizontal Chain-Grate Thermal Oil Boiler
Model / Series YLW
A box-coil heater with radiant and convective sections and chain-grate combustion. Outputs span 1200–16500 kW.
The YLW series uses box-shaped coils with flat-laid top tubes to protect the roof. Flames transfer radiant heat through coil walls; gas then enters the convective section and exits via the tail-end surfaces.
The chain grate and body are dispatched separately. Fuel feeding, ventilation by forced- and induced-draft fans, and slag removal are mechanical. Fuel drops onto the grate; gas is reflected by the rear arch toward the front, passes radiant and convective surfaces, then the waste-heat boiler, air preheater and dust collector before chimney discharge.
Design and features
Split packaged construction
The body and grate are transported as upper and lower sections and assembled on site.
Independent air chambers
Independent air chambers distribute combustion air along the grate.
Stepless speed control
Stepless grate-speed adjustment matches fuel characteristics and supports combustion regulation.
Radiant section
Two-pass rectangular coils and top coils form the radiant surfaces, with tube banks secured by welded round steel.
Convective section and baffles
A spiral reciprocating arrangement and flue-gas baffles control gas flow.
PRODUCT DATA
Specifications
| Detailed model designation: YLW-__rated heat output (kw)__MA | |||||||||
| Model | 1200 | 1400 | 2000 | 2400 | 3000 | 3500 | 4100 | 4700 | |
| Rated heat output | KW | 1200 | 1400 | 2000 | 2400 | 3000 | 3500 | 4100 | 4700 |
| X104Kcal/h | 100 | 120 | 160 | 200 | 250 | 300 | 350 | 400 | |
| Thermal efficiency | (≥%) | 76.46 | 77.7 | 78.08 | 78.08 | 78.47 | 78.5 | 79.2 | 79.5 |
| Design pressure | (MPa) | 1.1 | |||||||
| Maximum medium temperature | (℃) | 320 | |||||||
| Thermal oil circulation flow | (m3/h) | 100 | 100 | 160 | 180 | 200 | 200 | 250 | 250 |
| Oil volume in heater | (m3) | 1 | 1.1 | 1.9 | 2.2 | 2.38 | 3.1 | 3.4 | 3.8 |
| Pipe connection nominal diameter | (DN) | 150 | 150 | 150 | 150 | 200 | 200 | 200 | 200 |
| Total installed system power | (KW) | 43.45 | 43.45 | 65.75 | 70.75 | 86.75 | 89.35 | 118.05 | 132.55 |
| Overall length | (mm) | 4710 | 4710 | 5821 | 5821 | 6834 | 6814 | 6814 | 7214 |
| Overall width | (mm) | 2020 | 1930 | 2040 | 2040 | 2040 | 2500 | 2500 | 2500 |
| Overall height | (mm) | 3600 | 3808 | 4040 | 4349 | 4487 | 4487 | 4846 | 4874 |
| Total equipment weight | (Kg) | 17000 | 18000 | 25000 | 26100 | 34000 | 38600 | 40000 | 45000 |
| Continued | |||||||||
| Model | 6000 | 7000 | 8200 | 9300 | 12000 | 13900 | 16500 | -- | |
| Rated heat output X104Kcal/h |
KW | 6000 | 7000 | 8200 | 9300 | 12000 | 13900 | 16500 | -- |
| 500 | 600 | 700 | 800 | 1000 | 1200 | 1400 | -- | ||
| Thermal efficiency | (≥%) | 79.5 | 79.1 | 79.5 | 79.7 | 81.1 | 79.1 | 80.01 | -- |
| Design pressure | (MPa) | 1.1 | -- | ||||||
| Maximum medium temperature | (℃) | 320 | -- | ||||||
| Thermal oil circulation flow | (m3/h) | 300 | 340 | 400 | 520 | 600 | 800 | 1000 | -- |
| Oil volume in heater | (m3) | 4.6 | 7.5 | 10 | 11.2 | 12 | 13.5 | 16.5 | -- |
| Pipe connection nominal diameter | (DN) | 200 | 250 | 250 | 250 | 300 | 350 | 400 | -- |
| Total installed system power | (KW) | 179.75 | 180.9 | 180.9 | 269.4 | 375.8 | 375.8 | 520 | -- |
| Overall length | (mm) | 8850 | 9070 | 10250 | 11300 | 11830 | 12330 | 14450 | -- |
| Overall width | (mm) | 3040 | 3200 | 3200 | 3200 | 3320 | 3686 | 4500 | -- |
| Overall height | (mm) | 5235 | 5287 | 5432 | 5372 | 6070 | 5991 | 6605 | -- |
| Total equipment weight (Kg) | 59000 | 70000 | 86500 | 95400 | 105000 | 113845 | 162240 | -- | |
Related products

Vertical Thermal Oil Steam Generator
Multilayer circular coils indirectly heat water with thermal oil. Steam generation is 0.1–2 t/h.
View product
Horizontal Thermal Oil Steam Generator
A tube-bundle and drum assembly produces saturated steam from circulating thermal oil. Steam generation is 2–8 t/h.
View product
Vertical Oil/Gas-Fired Thermal Oil Boiler
A circular-coil thermal oil heater with burner and PLC control. Rated heat outputs span 120–14000 kW.
View product